-40%

SOLAREDGE P370-5 SERIES DC OPTIMIZER FOR SINGLE MODULES UP TO 370 WATTS

$ 50.16

Availability: 100 in stock
  • MPN: P370-5
  • Restocking Fee: No
  • Item must be returned within: 30 Days
  • All returns accepted: Returns Accepted
  • Brand: Solaredge
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Condition: New
  • Model: P370-5
  • Return shipping will be paid by: Seller

    Description

    SolarEdge
    Power Optimizers
    The
    SolarEdge Power Optimizer
    is a DC/DC converter which is connected by installers to each PV module, replacing the traditional solar junction box. The SolarEdge power optimizers increase energy output from PV systems by constantly tracking the maximum power point (MPPT) of each module individually. Furthermore, the power optimizers monitor the performance of each module and communicate performance data to the SolarEdge monitoring portal for enhanced, cost-effective module-level maintenance. Each power optimizer is equipped with the unique SafeDC™ feature which automatically shuts down modules' DC voltage whenever the inverter or grid power is shut down. The MPPT per module allows for flexible installation design with multiple orientations, tilts and module types in the same string. When working with SolarEdge Inverters, SolarEdge power optimizers automatically maintain a fixed string voltage, allowing installers even greater flexibility with longer strings and strings of different lengths in order to design optimal PV systems. The SolarEdge power optimizers are compatible with c-Si and thin-film modules and have a 25 year warranty.
    FEATURES:
    Ease of installation - simply clip the power optimizer to the module frame or attach to the rail with a single screw
    Only requires equipment grounding - with a single star washer (included) between the optimizer and the racking (grounding lugs not needed)
    For Single Phase Inverters
    Connects one module per optimizer
    Up to 25% more harvested energy from your PV system
    Per-module Maximum Power Point Tracking (MPPT)
    Superior efficiency (99.5% peak efficiency, 98.8% weighted efficiency)
    Mitigates all types of modules mismatch-loss, from manufacturing tolerance to partial shading
    Allows for parallel strings of different lengths or orientations
    Designed for extreme environmental conditions
    Advanced, real-time performance measurement
    Automatic module DC voltage shut-down for installer and firefighter safety. Each optimizer has an internal temperature sensor which detects if it gets over 185 degrees °F - and they shut down, if reached.
    25 Year Warranty
    ELECTRICAL CHARACTERISTICS:
    SPECIFICATIONS
    P320 Optimizer
    (high power
    60-cell modules)
    P370 Optimizer
    (60/72-cell modules)
    P400 Optimizer (72/96-cell modules)
    P505 Optimizer (higher current modules)
    Rated Input DC Power
    320W
    370W
    400W
    505W
    Absolute Max Input Voltage
    48Vdc
    60Vdc
    80Vdc
    83Vdc
    MPPT Operating Range
    8-48 Vdc
    8-60 Vdc
    8-80 Vdc
    12.5-83 Vdc
    Max Short Circuit Current (Isc)
    11A
    11A
    10.1A
    14A
    Max DC Input Current
    13.75A
    13.75A
    12.5A
    17.5A
    Max/Weighted Efficiency
    99.5% / 98.8%
    Max Output Current
    15A
    Max Output Voltage
    60Vdc
    60Vdc
    85Vdc
    85Vdc
    Safety Output Voltage per Optimizer (during standby)
    1 Vdc
    INSTALLATION SPECIFICATIONS
    Max Allowed System Voltage
    1000 Vdc
    Input Connector (Modules)
    MC4 compatible
    Output Wire Type/Connector (Optimizers)
    PV Wire / MC4
    Output Wire Length
    3 ft (.95 m)
    3.9 ft (1.2 m)
    Operating Temp Range
    -40 to +85°C / -40 to +185°F
    Max/Weighted Efficiency
    99.5% / 98.8%
    Relative Humidity
    0 - 100%
    Protection Rating
    IP68 / NEMA6P
    Optimizer String Length (Min- Max)
    8 - 25
    Max Power per String
    5250W
    **NOTE:
    P300/P400 optimizers can be combined in one string. P600/P700 optimizers can be combined in one string. It is not allowed, however, to mix P600/P700 optimizers with P300/P400 optimizers in one string.